|
|
-
4.0 of 5.0 with 9 Reviews
SALE PRICE: $42.64 1% OFF
Manufacturer: Miljoco
Brand: Miljoco
Model: SX93588
Color: Blue organic-filled glass tube
Manufacturer: Miljoco
Brand: Miljoco
Model: SX93588
Color: Blue organic-filled glass tube
Industrial thermometer, 9" cast aluminum case, acrylic lens, blue spirit-filled liquid in glass, adjustable angle 3.5" aluminum stem with 1-1/4" 18 UNF brass coupling nut, 30 to 180°F / 0 to 80°C temperature range.
-
4.0 of 5.0 with 9 Reviews
SALE PRICE: $17.87
Manufacturer: Bel-Art
Brand: SP Scienceware
Model: B61310-3300
Manufacturer: Bel-Art
Brand: SP Scienceware
Model: B61310-3300
This DURAC bi-metallic dial thermometer features a 33mm (1.3in) dial and a 125mm (4.9) probe. Thermometer has a minimum immersion of 50mm (2in) in liquids or 100mm (4in) in gases. The external adjustment nut allows for simple field calibration. Thermometer also features a polycarbonate lens and probe cover with a pocket clip. Each thermometer is individually packaged with a multi-language (English, French, German, Italian, Portuguese and Spanish) Statement of Test and Calibration. Range: -40 To 70°C (-40 To 160°F). Divisions: 2. Dial Size: 33mm (1.3in). Probe Length: 125mm (4.9in). Per Each. HB Instrument #: 9/2120.
-
4.0 of 5.0 with 9 Reviews
SALE PRICE: $114.41 42% OFF
Manufacturer: Midland Scientific
Brand: VeeGee
Model: 43036
Manufacturer: Midland Scientific
Brand: VeeGee
Model: 43036
Scale: salinity/specific gravity of seawater range: 0-100 percent/1.000-1.070 resolution: 1.0 percent/0.001. This product is manufactured in United States.
-
4.0 of 5.0 with 9 Reviews
SALE PRICE: $19.17 2% OFF
Manufacturer: Kimble Chase
Brand: Kimble
Model: 9521400100
Manufacturer: Kimble Chase
Brand: Kimble
Model: 9521400100
This salimeter is graduated from 0-100% saturated sodium chloride. It is used in the measurement of meat packing and pickling brines. It meets or exceeds the requirements in ASTM specification E100, and it is calibrated to ASTM specification E126 to ensure accuracy. A serial number is printed on the scale and a certificate of traceability is included. The certificate of traceability indicates that the hydrometers are manufactured using devices calibrated using NIST traceable standards. The ballast is made from steel pellets and a binder, and it is free of heavier metals.
-
3.9 of 5.0 with 9 Reviews
SALE PRICE: $102.35 1% OFF
Manufacturer: Dwyer Instruments, Inc.
Brand: Dwyer
Manufacturer: Dwyer Instruments, Inc.
Brand: Dwyer
THE MODEL IR2 INFRARED TEMPERATURE THERMOMETER allows users to economically take accurate measurements in hard to reach areas. Measurements can be taken at a safe distance with a 9:1 Distance to Target Ratio. The IR2 easily takes measurements within 2% accuracy using a built-in laser sighting. The fixed emissivity of 0.95 is perfect for measuring surface temperatures of concrete, asphalt, rubber or oxidized metals. Besides reading the process temperature, the back lit display also reads the maximum temperature seen. Excellent for monitoring surface temperatures of air ducts, boilers, engines or light fixtures.
-
3.9 of 5.0 with 9 Reviews
SALE PRICE: $39.39 31% OFF
Manufacturer: Winters
Brand: Winters Instruments
Model: TBM30090B13
Manufacturer: Winters
Brand: Winters Instruments
Model: TBM30090B13
-
3.9 of 5.0 with 9 Reviews
SALE PRICE: $38.98 1% OFF
Manufacturer: Home Brew Stuff
Brand: Home Brew Ohio
Manufacturer: Home Brew Stuff
Brand: Home Brew Ohio
Big Daddy dial thermometer;Stainless clip to clip to brewing kettle;+-2% accuracy;Appropriate brewing range 0 - 220 degrees F
-
3.9 of 5.0 with 9 Reviews
SALE PRICE: $199.00
Manufacturer: ATAGO
Brand: Atago
Model: 4101
Manufacturer: ATAGO
Brand: Atago
Model: 4101
Range: 0.00-10.0 percent salt concentration by weight sample temperature: 5 to 100°c/ambient temperature: 10 to 40°c resolution: 0.01 percent (up to 2.99 percent salt), 0.1 percent (above 3.00 percent salt), 0.1°C accuracy: ±0.05 percent (up to 0.99 percent salt), relative precision of ±5 percent (above 1.00 percent salt), ±1°c 3.1×10.9×5.5cm 100G, IP rating: IP65/power supply: two (2) AAA alkaline batteries
-
3.9 of 5.0 with 9 Reviews
SALE PRICE: $61.35 1% OFF
Manufacturer: Thomas Scientific
Brand: Thomas
Manufacturer: Thomas Scientific
Brand: Thomas
The Thomas Scientific API hydrometer for petroleum testing is available in a variety of ranges on the API (American Petroleum Index) scale.Thomas Scientific manufactures instruments, equipment, supplies, and chemicals for laboratory and scientific applications. The company, founded in 1900, is headquartered in Swedesboro, NJ.Â
-
3.9 of 5.0 with 9 Reviews
SALE PRICE: $43.99 5% OFF
Manufacturer: Bel-Art
Brand: SP Scienceware
Model: B61821-0700
Manufacturer: Bel-Art
Brand: SP Scienceware
Model: B61821-0700
Made of lead free ballast and glass, these combined form thermo-hydrometers are 381mm (15") long and offer the additional convenience of an enclosed thermometer with a temperature scale of 0/150 degrees F and mercury-free blue spirit organic liquid fill. They are individually serialized and conform to the accuracy requirements for ASTM thermo-hydrometers. Specific gravity hydrometers are the most widely used hydrometer in industries such as food and beverage, chemistry, pharmacology, transportation, refrigeration and more. Choose from a wide range of models measuring specific gravity/relative density (g/cm3) of a variety of liquids in various ranges from 0.600 to 2.000. Temperature standardization is 60 degrees F (15 degrees C). DURAC Safety Combined Form Thermo-Hydrometers are hand inspected by our U.S. quality team in our exclusive triple accredited/registered ISO/IEC 17025:2005 and A2LA Accredited Calibration Laboratory; internationally recognized and accepted by the signatory economies of the ILAC /MRA and located in our ISO 14001:2004 Environmental Management System registered facility. They are packaged with a multi-language (English, French, German, Italian, Portuguese, and Spanish) Statement of Accuracy indicating accuracy traceable to NIST. Note: Combined form hydrometers should be stored in a clean, dry, safe place, and should not be subjected to extreme temperatures. Enclosed thermometers should be used as a general reference only. For temperature critical applications, a calibrated standard thermometer is recommended.
|
|